Communication Manager Maintenance-Object Repair Procedures
994 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Table 343: Test #135 Internal Loop-Around Test
Error
Code
Test
Result
Description / Recommendation
2012 ABRT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1002 ABRT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due
to TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at 1-minute intervals up to 5 times.
1003 ABRT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present, or some Tone
Detectors may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals up to 5
times.
1004 ABRT Received an incoming call on a port of the DS1 circuit pack during the test.
1. Enter busyout board location to put every trunk on the DS1
circuit pack into the out-of-service state.
2. Retry the command at 1-minute intervals up to 5 times.
1015 ABRT Ports on DS1 Interface circuit pack have not been busied out.
1. Enter busyout board location to put every trunk on the
DS1circuit pack into the out-of-service state.
2. Retry the command.
1039 ABRT The DS1 Interface circuit pack is providing timing for the system.
Therefore, it cannot be reset without major system disruption.
1. If the DS1 Interface circuit pack needs to be tested, set the
synchronization reference to another DS1 Interface circuit pack or to
the Tone-Clock circuit using the following command sequence:
a. Enter disable synchronization-switch
b. Enter set synchronization location
c. Enter enable synchronization-switch
1 of 3