Communication Manager Maintenance-Object Repair Procedures
1348 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS Hybrid Line Audits test passed.
1. Although this test never actually returns a FAIL result (except for the
previous Internal system error), it can enter Error Types 257 and 513
into the Error Log. To check for problems that don’t show up in the test
result, look for these error types in the Error Log.
2. If these errors appear in the Error Log, or if user complaints still exist,
investigate by using other circuit pack tests, and by examining the
station, wiring, and connections.
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Enter
list config, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, enter busyout
board location.
3. Enter reset board location.
4. Enter release board location.
5. Enter test board location long.
This should re-establish the linkage between the internal ID and the port. If
this is not the case, dispatch to check to ensure that there is a valid board
inserted.
Table 471: Test #61 Hybrid Line Audits Test (continued)
Error
Code
Test
Result
Description / Recommendation