Communication Manager Maintenance-Object Repair Procedures
2188 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
k. Error 6103: an application alarm occurred on the standby server. See note (l) to diagnose
the error using the Aux Data.
l. Error Types 6002, 6003, 6102, and 6103: the aux-data value points to the MO that the
error or alarm is logged against. The following table lists possible aux-data values and their
associated MOs. Locate the Error Log entry for the indicated MO and follow the instructions
for that error.
m. Aux Data: Table 781
and notes give causes and recommendations for each Aux Data value
for Error Type 605.
Aux Data Implicated MO
4137 PKT-INT
16384 PROCR
16385 MEM-BD
16389 DUPINT
16391 SW-CTL
16392 H-ADAPTR
16397 R-MEDIA
16398 DISK
Table 781: SYSTEM Error 605 Aux Data, Failure of Planned Interchange
Aux
Data
See
Note
Explanation
1352 (a
) 1 Standby SOH "non-functional"
1353 (a
) 1 Standby SOH not "functional"
1355 (a
) 1 Handshake Communication with standby server is down
1356 (a
) 1 Memory Shadowing not enabled
1357 (a
) 1 Standby memory not refreshed
1358 (b
) 2 Mass Storage System was in use
1359 (c
) 3 PKT-INT link migration failed
1360 (a
) 1 Interchange failed
1 of 2