EMG-XFER (Emergency Transfer)
Issue 1 June 2005 1141
Emergency Transfer Query Test (#124)
The Emergency Transfer Query test queries the hardware for the state of the Emergency
Transfer switch and reports the result. If the position of the switch in a PN cabinet is such that
the system software can control Emergency Transfer (auto), then the test passes. If the position
of the switch or switches is such that the system software cannot control Emergency Transfer
(manual “on” or manual “off”), then the test fails. Maintenance Tone-Clock controls Emergency
Transfer.
Table 392: Test #124 Emergency Transfer Query Test
Error
Code
Test
Result
Description / Recommendation
1000 ABRT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2000 ABRT Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to ABORT with Error Code 2000, check for
system powering problems with the PN’s A carrier. Resolve every
AC-POWER and CARR-POW alarm in a multicarrier cabinet system
or DC-POWER alarm in a single-carrier cabinet system. Then,
repeat the test.
3. If the test continues to ABORT with a 2000 Error Code, resolve every
or MAINT (Maintenance circuit pack) error in a PN. Then, repeat the
test.
2029
2319
2320
2500
ABRT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
17
18
20
33
65
289
FAIL Emergency Transfer is manually turned OFF (Emergency Transfer
switch off).
1. Place the switch in the AUTO position.