Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
POW-SUP (power supply)
Issue 1 June 2005 1883
Error log entries and test-to-clear values
Table 687: POW-SUP Hardware Error Log
Error
Type
Aux
Data
Associated test Alarm
level
1
1. This is a MINOR alarm if there is a redundant power supply, and a MAJOR alarm if there is only one
power supply.
On/Off
board
Test-to-clear value
1 (a
)
Any Power supply detection test
(#1535)
MAJ
MIN
ON test environment location
test board location
recycle carrier location [override]
23 (b
)
Power supply recycle test
(#1534)
WRN ON test environment location
test board location
recycle carrier location [override]
257 (c
)
Power supply recycle test
(#1534)
MAJ
MIN
ON test environment location
test board location
recycle carrier location [override]
513 (d
)
Power supply voltage test
(#1536)
MAJ
MIN
ON test environment location
test board location
recycle carrier location [override]
769 (e
)
Power supply voltage test
(#1536)
MAJ
MIN
ON test environment location
test board location
recycle carrier location [override]
1025 (f
)
Power supply voltage test
(#1536)
MAJ
MIN
ON test environment location
test board location
recycle carrier location [override]
1281 (g
)
Power supply voltage test
(#1536)
MAJ
MIN
ON test environment location
test board location
recycle carrier location [override]
1537 (h
)
Any Power supply voltage test
(#1536)
MAJ
MIN
ON test environment location
test board location
recycle carrier location [override]
1793 (i
)
Any Power supply voltage test
(#1536)
MAJ
MIN
ON test environment location
test board location
recycle carrier location [override]
2049 (j
)
Power supply voltage test
(#1536)
MAJ
MIN
ON test environment location
test board location
recycle carrier location [override]