Communication Manager Maintenance-Object Repair Procedures
414 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Station Status and Translation Audits and Updates Test (#36)
This test updates the analog port’s message lamp state (if it has one) and translations (such as
station type, dial type, network connection) with information kept in the software. The software
is updated with the switchhook state reported by the port processor. When the ringer is in the
off state, this test also turns off the station’s ringer to prevent constant ringing caused by
defective hardware.
Table 122: Test #36 Station Status and Translation Audits and Updates Test
Error
Code
Test
Result
Description / Recommendation
ABRT Could not allocate the necessary system resources to run this test.
1004 ABRT System resources required to run this test are not available. The port may
be busy with a valid call.
1. Use display port location to determine the station extension.
Use status station to determine the service state of the port. If
the service state indicates that the port is active, then the port is
unavailable for certain tests. Wait until the port is idle before retesting.
2. Retry the command at 1-minute intervals up to 5 times.
3. If the test continues to abort and the port is idle, escalate the problem.
1005 ABRT The test was aborted due to a configuration problem. This error code
occurs under either of the following conditions:
1. This test may not be applicable, or it may be disruptive to terminal
equipment other than a voice terminal (for example, the modem pool
member or music on hold).
2. The circuit pack is one of the following:
- TN742 vintages 13,14, and 15
- TN769 vintages 3, 4, and 5
1 of 3