ATM-BCH (ATM B-Channel Trunk)
Issue 1 June 2005 513
System Technician-Demanded Tests:
Descriptions and Error Codes
Investigate tests in the order presented. When you clear one of the error codes associated with
a given test, you clear errors generated by other tests in the testing sequence.
Signaling Link State Audit Test (#255)
This nondestructive test checks the status of the TN230x ATM-CES Interface circuit pack and
the ATM D-channel (ATM-DCH) trunk, which are both important elements to the health of the
ATM-BCH trunk.
Table 160: System Technician-Demanded Tests: ATM-BCH
Order of Investigation Short
Test
Sequence
Long Test
Sequence
D/ND
1
1. D = Destructive, ND = Nondestructive
Signaling Link State Check test (#255) X X ND
Service State Audit test (#256) X X ND
Call State Audit test (#257) X X ND
ISDN Test Call test (#258) X ND
Table 161: Test #255 Signaling Link State Audit Test
Error
Code
Test
Result
Description / Recommendation
None ABRT Internal system error
0 ABRT 1. Retry the command up to 5 times at 1-minute intervals.
1114 ABRT Signaling link in transitional state
1. Retry the command up to 5 times at 1-minute intervals.
1018 ABRT Maintenance disabled
1. Enable maintenance. Enter y in the Maintenance Tests field on the
change trunk-group screen.
1 of 2