ETH-PT (Control LAN Ethernet)
Issue 1 June 2005 1157
Table 397: Test #1278 Ethernet Local Loop-Around Test
Error
Code
Test
Result
Description / Recommendation
1000 ABRT The port is in use.
1. Determine status of port (status clan-port location).
2. Retry the command when the port is idle. You can force the port to the
idle state by executing busyout port location.
!
CAUTION:
CAUTION: The busyout port command is destructive, causing
every call and link associated with the port to be torn down.
2000 ABRT Did not receive circuit pack test response within the allowable time period.
1. If the problem persists, reset the circuit pack (busyout board
location, reset board location, and release board
location).
2. If the problem persists, replace the circuit pack.
2012 ABRT Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. If the problem persists, escalate the problem.
2100 ABRT Could not allocate the necessary resources to run test.
1. Retry the command at 1-minute intervals, up to 5 times.
2. If the problem persists, escalate the problem.
1 FAIL Circuit pack detected failure in the Ethernet Local Looparound test
(#1278).
1. If the problem persists, reset the circuit pack (busyout board
location, reset board location, and release board
location).
2. If the problem persists, replace the circuit pack.
PASS The circuitry tests properly.