CO-TRK (Analog CO Trunk)
Issue 1 June 2005 843
Note:
Note: A Demand Diagnostic test (#3) will always return a PASS indication for CO-TRK/
CO-BD [TN747B] version 8 or greater. However, any errors produced as a result
of this test will be logged and produce no alarms.
If errors logged by Test #3 are the only complaints against this trunk, then the
system technician should check if MFT/Range Extenders are being used. If
extenders are present, then there is a good chance that there is excessive loop
current, which will cause Test #3 to log errors.
However, all else being normal, these errors should not affect the customer.
Note:
Note: The ATMS tests are not part of either test sequence. They are run either on
demand with test analog-testcall or by the ATMS schedule.
Dial Tone Test (#0)
This test attempts to seize a port and checks for the return of a dial tone.
Audit Update test (#36) X X ND
Transmission test - ATMS (#844-848)
S8300 / G700 aborts with Error Code 1412
ND
1. D = Destructive; ND = Nondestructive
Order of Investigation Short Test
Sequence
Long Test
Sequence
D/ND
1
2 of 2
Table 288: Test #0 Dial Tone Test
Error
Code
Test
Result
Description / Recommendation
ABRT Could not allocate system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1 of 4