Signaling Link Board Check (#643)
This nondestructive test checks the health of the ATM TN230X trunk circuit pack’s hardware.
The test runs on a periodic or scheduled basis, during initialization testing, and upon demand.
Note:
Note: The board-level maintenance is handled independently of the ATM-CES
signaling link maintenance, raising the possibility of inconsistent states.
Error
Code
Test
Result
Description / Recommendation
ABRT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
8 FAIL The TN230X circuit pack is not in-service.
1. Check the Error Log for ATM-TRK errors and resolve any using
ATM-TRK (Circuit Emulation Service Circuit Pack)
on page 617.
PASS The ATM TN230X circuit pack is in-service.