HYB-LINE (Hybrid Line)
Issue 1 June 2005 1345
Hybrid Line Lamp Updates Test (#60)
For this test, the software lights the lamps on the terminal based on the status record contained
in the processor. The lamp updates will run only if the station is in service.
Table 470: Test #60 Hybrid Line Lamp Updates Test
Error
Code
Test
Result
Description / Recommendation
1 ABRT A request for a remote station lamp update aborted even though every
internal resource was correctly allocated.
1. Look in the error log for Error Type 18 (port busied out) for this port. If this
Error Type is present, release the port via release port location or
release station extension, and then run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
2 ABRT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
3 ABRT The station is in a ready for service or an out of service state. This may be
due to wiring or an unplugged or defective set.
1. Make sure terminal is connected and the wiring is correct.
2. Retry the command at 1-minute intervals up to 5 times.
1000 ABRT System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use display port location to determine the station extension
number of the port. Use status station to determine the service
state of the port. If the port is in use, wait until it is idle before testing.
2. If the port status is idle, then retry the command at 1-minute intervals up
to 5 times.
1392 ABRT This port is currently a TTI port and the test will not execute on it.
1. Verify that the port is a TTI port using either display port (the port is
a TTI port) or list config (shows a t for the port).
2. If list config or display port indicate that the port is not a TTI
port, escalate the problem. If both commands indicate that the port is a
TTI port, the abort is correct, and no action is necessary.