Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
ISDN-TRK (DS1 ISDN Trunk)
Issue 1 June 2005 1471
1118 ABRT Far end of ISDN trunk is not administered.
1. Check the administration of the far-end ISDN trunk.
2. Enter status trunk grp#/mem#.
3. Try the test again.
1119 ABRT The test call was aborted due to a normal call attempt on this trunk.
The test call will only be performed if the trunk is idle.
1. Either wait for the normal call to finish normally, or force it to be
dropped by using busyout trunk grp#/mem# to busyout the DS1
ISDN Trunk. When the trunk is idle, retry the test.
1120 ABRT The DS1 ISDN Trunk is in the ISDN out-of-service/far-end state.
1. Try to change the service state via Test #256 (Service State Audit Test)
and then try this test again. Keep in mind that the trunk may be in the
out-of-service/far-end state due to problems at the far-end switch. If
that is the case, no remedial action can be taken at this end.
1122 ABRT There is no test line number for the far-end switch.
1. Check the Trunk Group administration form.
1123 ABRT There is no Feature Access Code administration for this Facility Test.
1. Check the Dial Plan and Feature administration forms.
S8300 /
G700:
1412
ABRT This test does not execute on a G700 Media Gateway.
2000,
2012,
None
ABRT Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
2035 ABRT The call has timed out, perhaps because of a lack of system resources.
1. Wait 1 minute and try again.
2036,
2037
ABRT Internal system error.
1. Follow recommendation for ABORT code 2012.
2038,
2039
ABRT A problem occurred while trying to read the test data.
1. Wait 1 minute and then try again. If the test aborts again in the same
manner, there is a serious internal problem.
Table 530: Test #258 ISDN Test Call (continued)
Error
Code
Test
Result
Description / Recommendation
3 of 6