Communication Manager Maintenance-Object Repair Procedures
678 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
LEDS
The ISDN-BRI Line circuit pack performs extensive initialization tests and lights both the red
and green LEDS during the initialization testing. See Chapter 3: LEDs
, for more details on
circuit pack status LEDs.
Hardware Error Log Entries and Test to Clear Values
Table 228: BRI-BD Error Log Entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
0 (a) 0 Any Any Any test board location sh r 1
1(b
) Any None MIN ON
18(c
)0 busyout board
location
WRN OFF release board location
23(d
) 0 None WRN OFF
257(e
) 65535 Control Channel
Loop (#52)
MIN ON test board location r 20
513(f
) 4352 to
4357
769(g
)4358
1025(h
) 4363 NPE Audit test
(#50)
1293
1294 (i
)
46088
to
46096
SAKI Sanity test
(#534)
MIN ON See Note (h
)
1537
1538 (j
)
46082 MIN ON
1793 (k
) 46080 MIN ON
1794 (k
) 46094 MIN ON
1795 (k
) 46085 MIN ON
1 of 2