Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
Communication Manager Maintenance-Object Repair Procedures
574 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Notes:
a. Error Type 23: The ATM expansion interface circuit pack is administered through a change
circuit-pack command, but has not been inserted into the system. Insert the circuit
pack.
b. Error Type 125: A wrong circuit pack is located in the slot where this circuit pack is logically
administered. To resolve this problem either remove the wrong circuit pack or insert the
logically-administered circuit pack.
c. Error Type 217: The ATM circuit pack is physically present but has not been given a
personality. Remove the circuit pack or administer it using add atm pnc or add atm
trunk.
System Technical Demanded Tests: Descriptions and Error Codes
Test failure is not logged in the error log.
Control Channel Loop-Around Test
This test queries the circuit pack for its circuit-pack code and vintage, and verifies its records.
Order of Investigation Short Test
Sequence
Long Test
Sequence
D/ND
Control Channel Loop Around test (#52) X X Nondestructive
Table 188: Test #52: Control Channel Loop-Around
Error
Code
Test
Result
Description / Recommendation
2000 ABRT The response to the test request was not received within the allowable time
period.
2100 ABRT The system resources required to this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2500 ABRT Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
1 of 2