ATM-TRK (Circuit Emulation Service Circuit Pack)
Issue 1 June 2005 647
ATM Cross Talk Test (#1298)
This nondestructive ATM Cross Talk test makes sure that TDM time slots are correctly allocated
to connections. It is useful for diagnosing one-way or noisy connections. The test fails if the
TDM programmable logic and/or the interface to the DSP is not operating properly. The test
can take more than 10 minutes.
0
NO
BOARD
No board detected.
1. Check the Error Log for wrong board Error 125 (wrong board) or Error
131 (no board). Replace or insert the circuit pack if necessary.
2. Check that the board is properly translated and inserted.
3. If Error 1538 (hyperactivity) is listed in the Error Log, and run reset
board location.
4. Run the test again, and, if it fails, replace the ATM-TRK circuit pack.
5. Retest.
Table 220: ATM Board DSP Test (#1293) (continued)
Error
Code
Test
Result
Description / Recommendation
3 of 3
Table 221: ATM Crosstalk Test (#1298)
Error
Code
Test
Result
Description / Recommendation
ABRT Could not allocate required system resources.
1. Retry the command up to 5 times at 1-minute intervals.
1002 ABRT Could not allocate time slots. Traffic could be heavy or time slots could be
out-of-service.
1. Identify and correct TDM-bus errors (if any) using the procedures in
the TDM-BUS (TDM Bus) MO.
2. Repeat the test up to 5 times at 1-minute intervals.
1 of 2