Communication Manager Maintenance-Object Repair Procedures
2300 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Slip Query Test (#1244)
This test is nondestructive.
Slips occur when the transmitter and receiver are not running at precisely the same clock rate.
The Slip Alarm Inquiry Test polls the total number of slips that have occurred on a link. When the
MM720 detects a slip condition, maintenance software initiates the Slip Alarm Inquiry Test to
query the slip counters on the MM720 and total the slip counts in the maintenance software. If
the slip count is over the threshold, a Minor alarm is raised against the MM720, leaving all ports
of the MM720 in the in-service state.
1187 ABRT The media module or port might have been busied out.
1. Look in the Error Log for Error Type 18 (busied out) for TBRI-BD or
TBRI-PT. If this Error Type is present for TBRI-PT, then release the port
with the release port GGGVSpp command and run the test again.
2. If the error is present for both TBRI-BD and TBRI-PT, then release the
media module with the release board GGGVSpp command and run
the test again.
Note:
Note: When you release the media module, you release all ports
associated with it. If certain ports still need to be busied out,
use the busyout port GGGVSpp command to busy them
out.
3. Make sure the terminal is connected.
4. Retry the command at 1-minute intervals a maximum of 5 times.
2012 ABRT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS The switch has successfully sent a Status Enquiry message.
Table 825: TEST #1243 Layer 3 Query (continued)
Error
Code
Test
Result
Description/ Recommendation
2 of 2