1004 ABRT The port has been seized by a user for a valid call. Use status trunk to
determine when the port is available for testing.
1. Retry the command at 1-minute intervals up to 5 times.
1005 ABRT Trunk has been administered as incoming-only; transmission tests can only
be run on outgoing trunks.
1115 ABRT The near end test line on the TN771 circuit pack could not be allocated.
1. Verify that the TN771 circuit pack is in service and that port 1 is
administered and in service with status port.
2. Retry the command at 1-minute intervals up to 5 times.
1900 ABRT The test completion message was not received from the TN771 circuit
pack.
1. Test the TN771 circuit packs.
1901 ABRT This error occurs when the TN771 circuit pack uplinks a message that is
not the proper response for this test. The anticipated uplink messages are
seize, ring or answer.
1. Verify that the Trunk is administered properly.
1905 ABRT Intercept tone detected from far end.
1. Get the test line data and verify it with the far end. Dial the test number
manually to see if the TTL is reached. If it is not, then either the number
is wrong, or the far end is administered incorrectly.
1906 ABRT Reorder tone detected from far end.
1. See actions for Error Code 1905.
1907 ABRT Other unexpected tone detected from far end.
1. See actions for Error Code 1905.
1913 ABRT Audible Ring detected from far end.
1. See actions for Error Code 1905.
1914 ABRT Unidentified interrupted tone detected from far end.
1. See actions for Error Code 1905
Table 834: Test #844-848 Transmission Test (continued)
Error
Code
Test
Result
Description / Recommendation