Communication Manager Maintenance-Object Repair Procedures
2040 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test
sequence. Refer to each appropriate test’s description, and follow its recommended
procedures.
b. This error occurs when the active SNC determines that there is a problem communicating
with an SNI circuit pack in the same carrier via the connecting multiprocessor serial channel
used for transmitting CSCN messages. The slot location of the SNI with which the SNC
cannot communicate is given in Table 745: SNC-LINK Hardware Error Log Entries
on
page 2039.
1537 2 (c) 8 Failure audit (#777) MIN OFF test board location r 1
1793 1 (b
) 9 Failure audit (#777) MIN OFF test board location r 1
1793 2 (c
) 9 Failure audit (#777) MIN OFF test board location r 1
2049 1 (b
) 13 Failure audit (#777) MIN OFF test board location r 1
2049 2 (c
) 13 Failure audit (#777) MIN OFF test board location r 1
2305 1 (b
) 14 Failure audit (#777) MIN OFF test board location r 1
2305 2 (c
) 14 Failure audit (#777) MIN OFF test board location r 1
2561 1 (b
) 15 Failure audit (#777) MIN OFF test board location r 1
2561 2 (c
) 15 Failure audit (#777) MIN OFF test board location r 1
2817 1 (b
) 16 Failure audit (#777) MIN OFF test board location r 1
2817 2 (c
) 16 Failure audit (#777) MIN OFF test board location r 1
3073 1 (b
) 17 Failure audit (#777) MIN OFF test board location r 1
3073 2 (c
) 17 Failure audit (#777) MIN OFF test board location r 1
3329 1 (b
) 18 Failure audit (#777) MIN OFF test board location r 1
3329 2 (c
) 18 Failure audit (#777) MIN OFF test board location r 1
3585 1 (b
) 19 Failure audit (#777) MIN OFF test board location r 1
3585 2 (c
) 19 Failure audit (#777) MIN OFF test board location r 1
3841 1 (b
) 20 Failure audit (#777) MIN OFF test board location r 1
3841 2 (c
) 20 Failure audit (#777) MIN OFF test board location r 1
1. The location of the SNI with which the SNC cannot communicate.
Table 745: SNC-LINK Hardware Error Log Entries (continued)
Error
Type
Aux
Data
SNI
Slot
1
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
2 of 2