Alarms in Linux Media Servers
Issue 1 June 2005 77
Alarm Log Entries
These tests verify that the standby media server’s components are operating correctly.
Notes:
1. Event ID #1
SME_ARB test failed — This test determines the other server’s alarm-generation
capability by querying the local server’s Arbiter to report on the other server’s Remote
Alarm Service functionality. Both media servers must have their own alarm-generation
utilities. If the test fails 3 consecutive times, the following Major alarm is logged:
#1,ACT,SME,A,1,MAJ,Far-end alarm service is down
2. Event ID #2 Standby_PN_Check test failed — This periodic test:
1. Queries the standby media server about its PNs’ state of health
2. Compares the acquired information to an administered value
A failure indicates that a mismatch occurred and that the standby media server is out of
sync. If this test fails 2 consecutive times, the following Major alarm is logged:
#1,ACT,SME,A,2,MAJ,Standby Port-Network check failed
System Technician-Demanded Tests: Descriptions
and Error Codes
This MO provides no on-demand tests for system technicians.
Back to: Hardware MOs
Server-related alarms
Table 21: RALM-SVC Alarm Log Entries
EVENT
ID#
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Linux Test to
Clear Value
1 (1
) SME_ARB test MAJOR ON testdupboard
2 (2
) Standby_PN Check test MAJOR ON testdupboard