Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
IPMEDPRO (TN2602AP IP Media Resource 320)
Issue 1 June 2005 1395
2801 ABRT The IP Media Resource has not been administered on the change
ip-interface form.
2806 ABRT The system could not find any in-service IP Media Resources to use as a
destination for this test.
2807 ABRT The specified IP Media Processor has been disabled on the change
ip-interfaces form.
10XX
XX = PN #
FAIL The test tone was not successfully sent from the IP Media Resource
specified in the test command and not successfully received by an IP
Media Resource in the PN specified in the error code (XX). XX = PN
number.
The source to destination direction failed. The destination to source
direction was not tested.
1. Resolve all other board alarms for the specified source IP Media
Resource.
2. Resolve all other board alarms for the IP Media Resources in the
destination PN.
3. Use ping and traceroute to localize the problem to the
customer’s LAN/WAN IP network.
20XX
XX = PN #
FAIL The test tone was successfully sent from the IP Media Resource
specified in the test command and received by an IP Media Resource in
the PN specified in the error code (XX). XX = PN number.
The test tone was not successfully sent in the reverse direction. The
destination to source direction failed. The source to destination direction
passed.
1. Resolve all other board alarms for the specified source IP Media
Resource.
2. Resolve all other board alarms for the IP Media Resources in the
destination PN.
3. Use ping and traceroute to localize the problem to the
customer’s LAN/WAN IP network.
Table 493: Short IP 2-Way Transmission Test (#1505) (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 3