Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
Communication Manager Maintenance-Object Repair Procedures
1310 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Tone Detection Verification Test (#42)
This test verifies that the call-progress tone-detection and the tone-level measurement
capabilities of the GPTD port are functioning properly.
Table 452: Test #42 Tone Detection Verification Test
Error
Code
Test
Result
Description / Recommendation
ABRT The system was not able to allocate every resource needed for this test, or
there was an Internal system error.
1 ABRT The system could not allocate every resource needed to test the
call-progress tones.
1001 ABRT The system was unable to put the GPTD port in the appropriate mode to
test it.
1002 ABRT The system could not allocate time slots for the test connection. This can
happen when the system is heavily loaded. If the system is not heavily
loaded, then test the TDM-BUS via test tdm 1 or test tdm 2.
1. Retry the command at 1-minute intervals up to 5 times.
1003 ABRT The system could not allocate a Tone-Clock for the test connection. This
may be caused by a heavy load on the system or by a faulted Tone-Clock.
1. Check to see if there are any alarms against the Tone-Clock in the port
network where the test ABORTed. If so see the recommended
procedures for TONE-BD (Tone-Clock Circuit)
on page 2327 or
TONE-PT (Tone Generator)
on page 2353.
2. If a new Tone-Clock has been inserted, allow about 1 minute for
maintenance to run on the newly-inserted circuit pack.
3. Retry the command at 1-minute intervals up to 5 times.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
2006 ABRT The active Tone-Clock circuit pack or a Tone Detector circuit pack may not
be functioning properly.
1. Test the active Tone-Clock circuit pack in the port network with test
tone-clock location, and see TONE-BD (Tone-Clock Circuit)
on
page 2327 for failures.
2. Retry the command at 1-minute intervals up to 5 times.
1 of 2