Communication Manager Maintenance-Object Repair Procedures
1144 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 0: Run the short test sequence first. If every test passes, run the long test
sequence. Refer to each appropriate test’s description, and follow its recommended
procedures.
b. Error 8801: the PN is unable to send up-link control messages, and the control channel of
the PN’s TDM bus is swapped as part of the recovery procedure.
c. Error 8803: the PN is unable to send up-link control messages and the PN’s Tone-Clock is
swapped as part of the recovery procedure.
d. Error 9901: the PN is unable to send up-link control messages, but recovers after the
control channels of the PN’s TDM bus are swapped.
e. Error 9902: the PN is unable to send up-link control messages, but recovers after the PN’s
active Tone-Clock is swapped.
f. Error 9903: the PN is unable to send up-link control messages, but recovers after a PNC
interchange has taken place.
g. Error 9904: the PN is unable to send up-link control messages, but recovers after a PN
WARM reset.
h. Error 9905: the PN is unable to send up-link control messages, but recovers after a PN
COLD reset.
Table 393: EPN-SNTY Error Log Entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
0 (a
)0Any None
8801 (b
) Any None
8803 (c
) Any None
9901 (d
) Any None
9902 (e
) Any None
9903 (f
) Any None
9904 (g
) Any None
9905 (h
) Any None