Communication Manager Maintenance-Object Repair Procedures
784 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to ABORT with error code 2000, check for system
powering problems with the PN’s A carrier. Resolve every
AC-POWER and CARR-POW alarm in a multicarrier-cabinet system or
DC-POWER alarm in a single-carrier cabinet system. Then, repeat the
test.
3. If the test continues to ABORT with a 2000 error code, resolve any
errors against the PN’s MAINT (Maintenance circuit pack). Then,
repeat the test.
2029,
2500
ABRT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
FAIL AC-POWERED SYSTEMS
There is a problem with one or both OLSs on the tested carrier.
1. For each OLS that has every status LED OFF, check the AC input to
the OLS at the OLS outlet. If there is no AC, then check the
appropriate fuses for the affected OLS. Replace open fuses. If the
fuses open again or AC does not show up at the OLS outlet, then there
is probably a power wiring problem in the cabinet.
2. At this point, AC should be present at the OLS outlet. Use recycle
carrier UUC (where UUC is the appropriate cabinet and carrier) in
an attempt to bring back the OLSs for this carrier. If the test passes,
the trouble is cleared. If the test does not pass, one OLS or both, in
the tested carrier is defective. If only one OLS is defective, then the
status LEDs on the healthy OLS will light green for a moment. When
the recycle test determines that both OLSs are defective, the software
will turn off power to both the good and defective OLSs. This will
cause the status LED(s) on the good OLS to light red.
3. Unplug both OLSs, and wait approximately 1-minute to allow the OLSs
to cool down. Plug in the OLSs. If either OLS is operating properly
(the status LEDs show green), then replace the defective OLS(s). See
OLS Replacement Procedures in this section.
Table 268: Test #127 OLS Query Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 5