Table 583: Test #61 MET Line Station Audits Test
Error
Code
Test
Result
Description / Recommendation
ABRT Internal system error
1 ABRT The test was aborted due to an internal system error during the
switchhook audit.
2 The test was aborted due to an internal system error during the bad scan
inquiry.
3 The test was aborted due to an internal system error during the EPF
audit inquiry.
1. Make sure that the station is not in an out-of-service state.
2. Retry the command at 1-minute intervals up to 5 times.
1000 ABRT System resources required to run this test are not available. The port
may be busy with a valid call.
1. Use display port location to determine the station extension
of the port. Use status station to determine the service state of
the port. If the port is in use, wait until the port is idle before testing.
2. If the port status is idle, then retry the command at 1-minute intervals
up to 5 times.
1004 ABRT The port was seized by a valid call during the test. The test has been
aborted.
1. Use display port location to determine the station extension
of the port. Use status station to determine the service state of
the port. If the port is in use, wait until the port is idle before testing.
2. Retry the command at 1-minute intervals up to 5 times.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL The test failed due to an internal system error.
1. Retry the command at 1-minute intervals up to 5 times.