PKT-INT (Packet Interface)
Issue 1 June 2005 1831
256
512
768
(
cont’d)
FAIL
(
cont’d)
5. If Error Code 512 or 768 is reported for an active IPSI’s Packet
Interface module, the receive FIFO in the PKT-INT has overflowed.
This may indicate the need for additional IPSI circuit packs.
For the current hardware configuration, only one IPSI circuit pack is
allowed per PN. Escalate the problem if not corrected by the
following repair steps. Retry the command after one minute if the test
continues to fail.
a. If the Packet Interface module is on the active IPSI (
S8700 MC: and
this is a high- or critical-reliability system), use set
ipserver-interface to perform a planned IPSI interchange.
Replace the standby IPSI circuit pack.
b. Otherwise, replace the IPSI circuit pack at a time that would cause
the least service disruption.
6. If Error Code 512 or 768 is reported for a standby IPSI’s Packet
Interface module, replace the standby IPSI circuit pack.
Table 672: Test #887 Read and Clear Board Counters (continued)
Error
Code
Test
Result
Description / Recommendation
3 of 4