Communication Manager Maintenance-Object Repair Procedures
1734 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
2000 ABRT Did not receive a response from a circuit pack being used for the test
within the allowable time period.
1. Reset the circuit pack (busyout board location, reset board
location, and release board location).
2. If the test fails again, replace the circuit pack.
2012 ABRT Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
2100 ABRT Could not locate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals, up to 5 times.
2. Escalate if the problem persists.
2500 ABRT Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
2801 ABRT No IP address defined.
1. Verify IP interfaces translations and retest.
2802 ABRT Different IP address pinged than software had allocated for the test.
1. Retry the command at 1-minute intervals up to 3 times.
2807 ABRT The board is administered but not enabled in the change
ipserver-interfaces screen.
1003 FAIL Ping to the destination failed due to on-board problems of the source of
the ping. The source of the ping can be a CLAN board or a IPMEDPRO
board for this error to occur.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Look for problems associated with IPMEDPRO or CLAN boards in
this region.
Table 642: Test #1417 Network Region Interconnectivity Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 3