TIE-DS1 (DS1 Tie Trunk)
Issue 1 June 2005 2283
0NO
BOARD
The test could not relate the internal ID to the port (no board). This
could be due to incorrect translations, no board is inserted, an
incorrect board is inserted, or an insane board is inserted.
1. Check to ensure that the board’s translations are correct. Use
list configuration, and resolve any problems that are
found.
2. If the board was found to be correctly inserted in step 1, enter
busyout board location
3. Enter reset board location
4. Enter release board location
5. Enter test board location long. This should re-establish
the linkage between the internal ID and the port. If this is not the
case, check to see that there is a valid board inserted.
Table 816: Test #7 Conference Circuit Test (continued)
Error
Code
Test
Result
Description / Recommendation
5 of 5