Communication Manager Maintenance-Object Repair Procedures
2536 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Table 902: Test #7 Conference Circuit Test
Error
Code
Test
Result
Description / Recommendation
ABRT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1000 ABRT System resources required to run this test are not available. The port may
be in use on a valid call. Use status access-endpoint extension to
determine when the port is available for testing.
1004 ABRT The port has been seized by a user for a valid call. Use status
access-endpoint extension to determine when the port is available
for testing. The port is available when it is in the in-service/idle state.
1. Retry the command at 1-minute intervals up to 5 times.
1020 ABRT The test did not run due to a previously existing error on the specific port or
because of a more general circuit pack error.
1. Examine the Error Log for existing errors against this port or circuit
pack, and attempt to diagnose the previously existing error.
G700:
1412
ABRT On the G700, this test aborts with Error Code 1412.
2000 ABRT Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL The NPE of the tested port did not conference the tones correctly. This
causes noisy and unreliable connections. Even though wideband calls do
not use the conferencing feature on the NPE, this failure indicates
problems with the circuit pack hardware.
1. Replace the circuit pack.
PASS The port can correctly conference multiple connections.
1. Investigate user-reported troubles on this port using other port tests
and by examining the terminal adapter or external wiring.