Communication Manager Maintenance-Object Repair Procedures
2496 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Receive FIFO Overflow Error Counter Test (#596)
This test is nondestructive. When the VAL circuit pack detects packet bus buffer overflow, it
increments the error on the FIFO Overflow error counter. This test reads and clears the counter.
If errors are occasional, then they can be due to statistical buffer sizing.
Table 883: Test #596 Receive FIFO Overflow Error Counter Test
Error
Code
Test
Result
Description / Recommendation
2000 ABRT Did not receive circuit pack test response within the allowable time period.
1. Retry command at 1-minute intervals up to 5 times.
2. If the problem persists, reset the circuit pack (reset board
location).
3. If the problem persists, replace the circuit pack.
2100 ABRT Could not allocate the necessary system resources to run test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the problem persists, escalate the problem.
2500 ABRT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2. If the problem persists, escalate the problem.
1–10 FAIL Circuit pack detects overflow errors. The Error Code indicates the value of
the on-board error counter.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to fail, execute the Packet Interface test (#598)
(test board location).
3. If Packet Interface test (#598) fails, see repair procedures for Test
#598.
PASS Circuit pack detects no errors.