Communication Manager Maintenance-Object Repair Procedures
426 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
AN-LN-PT (Analog Line Port)
S8700 | 8710 / S8500 / S8300 / G700
The TN793B/TN2793B Analog Line (w/ Caller ID) and the TN797 Analog Trunk and Line circuit
packs both support AN-LN-PT.
The TN793B/TN2793B Analog Line circuit pack (w/ Caller ID) provides 24 ports for voice
terminals and supports both on-premises and off-premises analog voice terminals.
Note:
Note: For DEFINITY G3i, si, and csi systems the TN793B/TN2793B analog line circuit
pack supports analog data modules. When assigned, analog data modules
provide access to the NetPkt (TN794 circuit pack) data ports. To activate an
analog data module you must assign the port location on the data screen and
connect a modem to the port. The analog data module can be used for
connection to a CDR output, or other adjuncts as needed. These ports are tested
like any other analog port on the circuit pack.
For S8500, S8700 products, CDR data is moved via LAN to a CDR adjunct.
The TN797 Analog Trunk and Line circuit pack provides 8 ports, each of which may be
administered in any of several ways, as described in MO TR-LN-BD.
S8300 / G700: The MM711 Analog Trunk and Line Media Module provides 8 ports, each of which
may be administered in any of several ways, as described in MO MG-ANA.
Note:
Note: Although the AN-LN-PT MO is provided for the G700 Media Gateways,
AN-LN-PT only partially supports the MM711 Analog Media Module.
Ringing caused by maintenance testing
Test #48 may cause some terminal equipment to ring briefly during daily maintenance. If this
ringing disturbs the customer or the terminal equipment, disable it in the Tests field of the
change station extension form. Be aware that this action also disables Tests #6, 7, 161,
and 35 on some software releases.
G700: Tests #6, 7, and 161 abort on the G700 with Error Code 1412.
MO Name in Alarm Log Alarm
Level
Initial Command to Run Full Name of MO
AN-LN-PT MIN test port location l Analog Line port
AN-LN-PT WRN test port location sh Analog Line port