DIOD-TRK (DIOD Trunk)
Issue 1 June 2005 971
1004 ABRT The port was seized by a valid call during the test. The test has been
aborted.
1. Enter display port location to determine the trunk group/
member number of the port. Use status trunk to determine the
service state of the port. If the port is in use, wait until it is idle before
retesting.
S8300
G700
1412
ABRT This test does not execute on a G700 Media Gateway.
2000 ABRT Response to the test was not received within the allowable time period.
1. Rerun the test at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
Any FAIL The NPE of the tested port was found to be transmitting in error. This
causes noisy and unreliable connections.
1. Replace the circuit pack.
PASS The port is correctly using its allocated time slots. User-reported troubles on
this port should be investigated by using other port tests and by examining
trunk or external wiring.
Table 334: Test #6 NPE Crosstalk Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2