ADX16D-P (16-Port AUDIX Digital Port)
Issue 1 June 2005 357
b. Error Type 1 with Aux Data 40987: The user may experience a noisy port or link, due to an
off-board problem that is detected by the port circuit. If so, replace the circuit pack (see
caution at the beginning of this section). Once the problem is resolved, the alarm is retired
after a predetermined time.
c. Error Type 1: At least 15 off-board problems have been detected with the link to the voice
port. When an error with the link is detected, an on-board counter is incremented. Also see
Note a above.
d. Error Type 15: An internal type error that occurs when an audit request fails.
e. Error Type 18: The port is busied-out by command. Release the port with release port
location.
f. Error Type 23: The circuit pack is administered but not physically installed. The alarm will
clear when a circuit pack is inserted.
g. Error Type 130: The circuit pack has been removed or has been insane for more than
21-minutes. To clear the error, reseat or replace the AUDIX circuit pack (see caution at the
beginning of this section).
h. Error Type 257: Something is interfering with transmission to the voice port. This is usually
an on-board problem and can be ignored if there are no user complaints.
i. Error Type 513: AUDIX is not available to the switch, possibly due to a busyout on the
AUDIX system. Refer to DEFINITY AUDIX System Release 3.2.4 Maintenance,
585-300-110.
j. Error Type 1537: An in-line maintenance error has generated an off-board warning due to
some problem with the link to the voice port. This can be ignored if there are no user
complaints. If the problem persists, replace the circuit pack (see caution at the beginning of
this section). Once the problem is resolved, the alarm is retired after a certain period of time.
k. Error Type 2305: The link between the circuit pack and the voice port is successfully reset.
No craft action is necessary.
l. Error Type 3840 with Aux Data 40965: No voice ports are connected to the EMBEDDED
AUDIX circuit pack. No maintenance action is required.
m. Error Type 3840 with Aux Data 41029: The message buffer in the circuit pack is full.