CO-TRK (Analog CO Trunk)
Issue 1 June 2005 857
Transmission Test (#844-848)
This test is nondestructive.
Note:
Note: S8300 / G700 The G700 Media Gateway does not support the Automatic
Transmission Measurement System. These tests abort with Error Code 1412.
Note:
Note: Tests #844 – 848 are not supported on an International switch.
These tests are run by the ATMS (Automatic Transmission Measurement System). They are
not part of the long or short trunk test sequences. Instead, they are run on demand with test
analog-testcall or as part of ATMS scheduled testing. For more information, see
Automatic Transmission Measurement System
in Maintenance Procedures (03-300192).
The test call is run from an analog port on a TN771 Maintenance/Test circuit pack. It attempts to
seize a port and make a call to a TTL (terminating test line) on the trunk’s far end. Transmission
performance measurements are made and compared to administered thresholds. Errors are
generated when results fall outside of “marginal” or “unacceptable” thresholds. Detail and
summary measurement reports are obtainable via list testcalls.
0
NO
BOARD
The test could not relate the internal ID to the port (no board).
1. Verify that the board’s translations are correct. Translate the
board, if necessary.
2. Enter busyout board location
3. Enter reset board location
4. Enter release board location
5. Enter test board location
This should re-establish the linkage between the internal ID and the
port.
Table 292: Test #36 Port Audit Update Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2