Communication Manager Maintenance-Object Repair Procedures
1768 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1340 ABRT No Maintenance/Test digital port is currently available to perform this test.
1. Use list config to determine whether any Maintenance/Test
digital ports (ports 02 and 03 on the Maintenance/Test circuit pack)
are present in the system. Because at least one Maintenance/Test
circuit pack must always be present in the PN of S8700
configurations, there should be at least two such ports present. If the
ports are present, proceed to step 2. Otherwise, determine why no
ports appear in the list config display. See M/T-DIG
(Maintenance/Test Digital Port) on page 1709 and M/T-BD
(Maintenance/Test Circuit Pack) on page 1705.
2. Look for M/T-DIG errors in the Error Log. If present, see M/T-DIG
(Maintenance/Test Digital Port) on page 1709.
3. If the ports are present and no errors are logged against them, retry
the command at 1-minute intervals up to 5 times.
4. If the test continues to abort, replace the Maintenance/Test circuit
pack.
1392 ABRT This port is currently a TTI port and the test will not execute on it.
1. Verify that the port is a TTI port using display port where the
display shows that the port is a TTI port, or list config, where the
display shows a t for the port.
2. If list config or display port indicate that the port is not a TTI
port, escalate the problem. If both commands indicate that the port is
a TTI port, the abort is correct for the test, and no action is necessary.
2005 ABRT The handshake between the Maintenance/Test digital port and the Data
Module failed.
1. Look for M/T-DIG errors in the Error Log. If present, see M/T-DIG
(Maintenance/Test Digital Port) on page 1709.
2. If test still aborts on retry, check physical connection of data module
under test. Make sure the switches are on NORM, OFF (between
REM_LP and LOC_LP), 9600, and ASYN.
3. If the test still aborts, replace the Data Module.
Table 654: Test #175 Data Module Internal Loop-Around Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 6