SNI-BD (SNI Circuit Pack)
Issue 1 June 2005 2083
112 FAIL The SNI circuit pack cannot communicate with the active SNC.
1. Check the error log for other SNI circuit packs in the same carrier with
a 257 SNI-BD error. Use display errors with category PNC to
view SNI-BD errors. If other SNI circuit packs in the same switch node
carrier have error 257, then replace the active SNC in this switch node
carrier. Replacing an SNC may be service interrupting. See SNC-BD
(Switch Node Clock Circuit Pack) on page 2000 for the procedure for
replacing an SNC. If other SNI circuit packs in the same carrier do not
have SNI-BD Error Type 257 logged, proceed to step 2.
2. Replace this SNI. Replacing an SNI may be service interrupting. See
SNI-BD (SNI Circuit Pack)
on page 2046 for the procedure for
replacing an SNI.
3. Replace the active SNC in the same switch node carrier. Replacing an
SNC may be service interrupting. See SNC-BD (Switch Node Clock
Circuit Pack) on page 2000 for the procedure for replacing an SNC.
113 FAIL The SNI circuit pack cannot communicate with the equipped SNI in slot
13.
1. Perform the Fiber link fault isolation
procedure in Maintenance
Procedures (03-300192). This will resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 2049, replace the
SNI being tested. Replacing an SNI may be service interrupting. See
SNI-BD (SNI Circuit Pack)
on page 2046 for the procedure for
replacing an SNI. To view SNI-PEER errors, use display errors
with category PNC-PEER. Retry the command.
3. If the SNI being tested has SNI-PEER Error Type 2049, replace the
SNI in slot 13. Replacing an SNI may be service interrupting. See
SNI-BD (SNI Circuit Pack)
on page 2046 for the procedure for
replacing an SNI. Retry the command.
Table 752: TEST #759 Configuration Audit (continued)
Error
Code
Test
Result
Description / Recommendation
7 of 13