ATM-BCH (ATM B-Channel Trunk)
Issue 1 June 2005 511
Outgoing call renegotiated by the far end to another B channel in the absence of SETUP
message glare
Near end attempted a call on a B channel that the far end has marked OOS
When running the short test sequence, pay close attention to the results of the Call State
Audit test (#257).
c. Error Type 129: the far-end switch changed its ISDN service state to either out-of-service
or maintenance. This may be a temporary condition because the far end is testing that
trunk or a hardware problem with the trunk. Outgoing calls may not be allowed over that
trunk.
1. Investigate the trunk’s status (status trunk grp#/mem#).
d. Error Type 130: the circuit pack has been removed or has been insane for more than 11
minutes.
1. Reinsert or replace the circuit pack to clear the error.
e. Error Type 257: SETUP received for a B channel that is in an invalid service state. Service
states may be incompatible at the two ends of the trunk. A normal call was received while
the B channel was MTC/FE, MTC/NE, OOS/FE, or OOS/NE or a test call was received
while the B channel was OOS/FE or OOS/NE.
f. Error Type 513: RELease COMplete message received with cause value 82 (nonexistent
channel). The B channel may not be administered at the far end. The trunk has been
placed in the OOS/FE state.
g. Error Type 769: inconsistent SERVice or SERVice ACKnowledge message. Possible
causes:
SERVice or SERVice ACKnowledge message received containing a change status that
is more available than the previously-transmitted SERVice message.
Unsolicited SERVice ACKnowledge message received containing a change status that
does not match the current B-channel state.
ISDN-PRI service-state negotiation rules have been violated and may indicate that a
pending service-state audit is failing. The system:
cancels the maintenance timer
increments the Service State Audit counter
attempts a Service State Audit
When running the short test sequence, pay close attention to the results of the Service State
Audit test (#256).
h. Error Type 1793: TN230x circuit pack failed. The maintenance system
places the trunk in the OOS/NE state
sends a SERvice message to the far end (if possible) containing a change status of OOS
for the B channel
returns the trunk to service when the ATM trunk circuit pack reports the failure cleared