DID-TRK (Direct Inward Dial Trunk)
Issue 1 June 2005 913
Port Audit Update Test (#36)
This test sends updates of the DID port translation for every port on the circuit pack or media
module that has been translated. The update is non-disruptive and guards against possible
corruption of translation data contained on the circuit pack or media module. No response
message is expected from the circuit pack or media module once it receives translation
updates. The port translation data includes:
● Wink or immediate start trunk
● Dial tone or rotary dialing trunk
● Rotary dialing inter-digit timing
● Network balance R/RC
● Disconnect timing
0
NO
BOARD
The test could not relate the internal ID to the port (no board).
1. Verify that the board’s translations are correct. Translate the board if
necessary.
2. Enter busyout board location
3. Enter reset board location
4. Enter release board location
5. Enter test board location
This should re-establish the linkage between the internal ID and the
port.
Table 310: Test #35 Port Diagnostic Test (continued)
Error
Code
Test
Result
Description / Recommendation
3 of 3
Table 311: Test #36 Port Audit Update Test
Error
Code
Test
Result
Description / Recommendation
ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1 of 2