Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
DID-DS1 (Direct Inward Dial Trunk)
Issue 1 June 2005 889
j. Error Type 2305 indicates that a signaling change was detected by the PBX trunk circuit
pack or media module which is inconsistent with the present state of the trunk.
k. Error Type 3840: Port Audit and Update test (#36) failed due to an internal system error.
Enter status trunk to verify the status of the trunk. If the trunk is out-of-service, enter
release trunk to put it back to in-service. Retry the test command.
System Technician-Demanded Tests:
Descriptions and Error Codes
Investigate tests in the order they are presented. By clearing error codes associated with NPE
Crosstalk, you may also clear errors generated from other tests in the sequence.
NPE Crosstalk Test (#6)
Note:
Note: S8300 / G700: This test aborts with Error Code 1412.
The NPE Crosstalk test verifies that this port’s NPE channel talks on the selected time slot and
never crosses over to time slots reserved for other connections. If the NPE is not working
correctly, 1-way and noisy connections may be observed. This test is usually only part of a
port’s long test sequence and executes in about 20 to 30 seconds.
Order of Investigation Short Test
Sequence
Long Test
Sequence
D/ND
1
1. D = Destructive; ND = Nondestructive
NPE Crosstalk test (#6)
S8300 / G700 Test aborts with Error Code 1412.
XND
Conference Circuit test (#7)
S8300 / G700: Test aborts with Error Code 1412.
XND
Port Audit and Update test (#36) X X ND
Table 304: Test #6 NPE Crosstalk Test
Error
Code
Test
Result
Description / Recommendation
ABRT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1 of 4