ASAI-PT
Issue 1 June 2005 495
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 0: Run the short test sequence first. If every test passes, run the long test
sequence. Refer to each appropriate test’s description, and follow its recommended
procedures.
b. Error Type 1: Level 1 Status inquiry fails or when the BRI circuit pack detects that Level 1
has been deactivated on the port. The Aux Data field contains one of the following values:
Refer to the repair procedures for Test #621.
Table 149: ASAI-PT Error Log Entries
Error
Type
Aux
Data
Associated
Test
Alarm Level
ASAI-
PORT
On/Off
Board
Test to Clear Value
0 (a
)0 Any Any Anytest port location sh r 1
1 (b
) (a) Level 1
Status
inquiry
(#621)
MAJ
1
1. Major and Minor alarms may be downgraded to warning alarms based on the value used in set options.
OFF test port location sh r 2
513 (c
) 0 none (b) ON
1537 (d
) 46210 CRC Error
counter
(#623)
MAJ1 OFF
3841 (e
) 46208 None
3844 (f
) 46223 None
3845 (g
) 46211 None
3846 (h
) TEI None
Blank This indicates that the Level 1 Status inquiry failed.
32773 This is a message from the ASAI-Line circuit pack indicating Level 1 has been
deactivated.