XXX-BD (Common Port Circuit Pack/Media Module)
Issue 1 June 2005 2547
System Technician-Demand Tests: Descriptions and Error Codes
Investigate tests in the order presented below. Clearing Error Codes associated with the one
test may also clear errors generated from other tests in the sequence.
Table 908: XXX-BD System Technician Demand Tests
Order of Investigation Short Test
Sequence
Long Test
Sequence
Reset Board
Sequence
D/
ND
1
1. D = Destructive; ND = Nondestructive
NPE Audit test (#50)
G700: Aborts with Error Code 1412 on G700/
G350
XND
Ringing Application test (#51)
Note: This test is applicable to TN746 and TN769
Analog Line circuit packs.
G700: Aborts with Error Code 1412 on G700/
G350
XX ND
Control Channel Loop-Around test (#52) X X ND
SAKI Sanity test (#53)
Note: The SAKI Sanity test is run in the long test
sequence for the Tone-Clock circuit packs
(TN768, TN780) only. The test is run on other
circuit packs or media modules only when they
are reset using reset board location.
XD
Neon test (#220)
Note: This test is applicable to TN746 and TN769
Analog Line circuit packs.
G700: Aborts with Error Code 1412 on G700/
G350
XX ND