Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
VC-BD
Issue 1 June 2005 2511
f. Error Type 769: the circuit pack detects a program logic error. While no action is required,
this error may lead to errors of other types being reported against this circuit pack.
g. Error Type 1025: the circuit pack cannot update NPE memory and read it back. This Error
Type can be ignored, but it may lead to other Error Types being reported against this circuit
pack.
h. Error Type 1281: a critical hardware failure has been detected on the circuit pack. Use
busyout board location, reset board location, followed by release board
location. If Test #53 passes, the on-board circuitry is healthy. Use test board
location long clear to retire the alarm. If Test #53 fails, replace the circuit pack.
i. Error Type 1293 and 1294: the circuit pack detected a critical hardware failure. Reset the
circuit pack with busyout board location, reset board location, and release
board location. If the Circuit Pack Restart test (#594) passes, then the on-board
circuitry is healthy. Retire the alarm by issuing test board location long clear. If
the Circuit Pack Restart test (#594) fails, replace the circuit pack.
The reported Error Types correspond to the following detected errors:
j. Error Type 1538: the circuit pack is hyperactive — it is flooding the switch with messages
sent over the control channel. The circuit pack is taken out of service when a threshold
number of these errors is reported to the switch. Clear the alarm by using busyout board
location, reset board location, test board location long clear, and
release board location. If the error recurs within 10 minutes, then replace the circuit
pack.
Error Type Description
1293 On-board auxiliary processor insane
1294 Internal memory access error