Communication Manager Maintenance-Object Repair Procedures
2338 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
S8700 | 8710
The following circuit-pack code(s) are supported:
S8700 MC:
TN768
This is a general-purpose Tone-Clock circuit pack for EPNs. It can be used in
every situation, except as the Master Tone-Clock circuit pack when a Stratum-3
clock is administered.
S8700 MC:
TN780
The Stratum-3 clock feature requires the use of this circuit pack code in PN 1.
The Stratum-3 clock will operate only with this code as the Master Tone-Clock
circuit pack. The TN780 circuit pack is upward compatible with the TN768 code,
and can be used in any place a TN768 would be allowed. The TN780 is used in
many countries outside the U.S. where the TN768 does not provide local tones.
S8700 MC:
TN2182
This Tone-Clock-Detector may be used anywhere a TN768 or TN780 is used,
with the exception of configurations requiring Stratum-3 clock. The TN2182 may
be used in all country configurations.
TN2312 The TN2312 IPSI circuit pack supplies Tone-Clock functionality for S8700
systems.
System Type Tone-Clock Circuit Pack Code
One-port network single-carrier cabinet system
without High or Critical Reliability.
TN756, TN768, TN780 TN2182
[G3iV4-386]
One-port network system without High or Critical
Reliability (multicarrier cabinet).
TN768, TN780
Two-port network single-carrier cabinet system
without High or Critical Reliability.
TN768, TN780 TN2182 [G3iV4-386]
One- or two-port network without High or Critical
Reliability.
TN768, TN780 TN2182 [G3iV4-386]