DID-DS1 (Direct Inward Dial Trunk)
Issue 1 June 2005 891
1004 ABRT The port was seized by a user for a valid call.
1. Use display port location to determine the trunk group/
member number of the port. Use status trunk to determine the
service state of the port. If the port is in use, wait until it is idle before
testing.
2. If the port status is idle, retry the command at 1-minute intervals up to
5 times.
1020 ABRT The test did not run due to a previously existing error on the specific port
or a more general circuit pack error.
1. Examine Error Log for existing errors against this port or circuit pack
and attempt to diagnose the previously existing error.
S8300 /
G700
1412
ABRT This test does not execute on a G700 Media Gateway.
2000 ABRT Response to the test was not received within the allowable time period.
1. Rerun the test at 1-minute intervals up to 5 times.
2100 ABRT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2053 ABRT At least one of the following errors is found on the DS1 circuit pack
(DS1-BD or UDS1-BD): 1281 – Loss of signal, 1793 – Blue Alarm, 2049 –
Red Alarm, 2305 – Yellow Alarm, or 1537 – Hyperactivity
1. Resolve any of the previous error types.
ANY FAIL This can be due to off-board problems, including EXP-PN and EXP-INTF
faults, RMC-ENV faults (
S8700 IP), TDM-BUS faults, and Tone Detectors/
Tone Generators. Clear every off-board problem before replacing the
board. A TDM-BUS problem is usually a faulty board or bent pins on the
backplane.
1. Resolve any EXP-PN, EXP-INTF, RMC-ENV (
S8700 IP), TDM-BUS,
TONE-BD, and TONE-PT errors in the error log.
2. Retest when errors are cleared. Replace the board if the test fails.
PASS The port is correctly using its allocated time slots. Investigate user-reported
troubles on this port using other port tests and by examining station, trunk,
or external wiring.