Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
Communication Manager Maintenance-Object Repair Procedures
2510 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test
sequence. Refer to each appropriate test’s description, and follow its recommended
procedures.
b. Error Type 1: the circuit pack stopped functioning or it was removed from the system. This
alarm is logged approximately 11 minutes after the circuit pack is removed and/or the SAKI
Sanity test (#53) fails.
To resolve this error, insert a circuit pack in the same slot as the error indicates, if the circuit
pack is not already in the system. Or, if the circuit pack is in the system and the red LED is
on, then follow instructions for Red alarms.
!
CAUTION:
CAUTION: If the TN788 Voice Conditioner circuit pack (VC-BD) is not Vintage 2 or later, it
must be replaced.
c. Error Type 18: this circuit pack is busied out by busyout board location.
d. Error Type 257: transient communication problems exist between the switch and this circuit
pack. Execute test board location and see the repair procedures for the Control
Channel Loop-Around Test (#52) on page 2512.
e. Error Type 513: the circuit pack detected an on-board hardware failure. The reported Aux
Data values correspond to the following detected errors:
Reset the circuit pack by executing busyout board location, reset board
location, and release board location. When it is reset, the circuit pack executes a
set of tests to detect the presence of any of the above faults. The detection of one these
errors during initialization causes the circuit pack to lock-up and appear insane to the
system. See the repair procedures in footnote (a) for Error Type 1.
1538 (j) 46082 MIN ON
Error Description
4352 External RAM error
4353 Internal RAM error
4355 ROM Checksum error
4357 Instruction set error
Table 890: VC-BD Error Log Entries (continued)
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
2 of 2