Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
ATM-EI (Expansion Interface Circuit Pack)
Issue 1 June 2005 547
1033 ABRT The test cannot run because either the ATM-EI board is not administered,
or there were no other PNs administered that had its ATM-EI board
in-service.
1. Ensure that the board is administered as ATM PNC Expansion
Interface circuit pack.
2. If the board is administered as ATM-EI circuit pack, then there has
been some change in the ability of the ATM-EI circuit pack in the other
PNs to communicate with the ATM-EI on the other end of its
connection.
3. Using status port x (the port-network number where the board is
administered), see if both ACL and EAL are up to this board. If not,
see the service procedure for SYS-LINK.
4. Check the Error Log for Error Type 1281 with Aux Data 27 (board
cannot talk to the ATM switch). See Table 172: Error type 1281 Aux
Data and repair procedures on page 538 for repair procedures.
5. If present, check both the ATM switch and the Communication
Manager translations for consistent ATM addresses. Reset the board,
and see if the problem resolves.
6. Repeat Test #241. If it continues to abort with this abort code, replace
the board.
1394 ABRT ABORT
1. See Table 172: Error type 1281 Aux Data and repair procedures
on
page 538 (Error Type 1281) with Aux Data 27 (board cannot talk to the
ATM switch), and if present, check both the ATM switch and the
Communication Manager translations for consistent ATM addresses.
2. Reset the board and see if the problem resolves.
3. Repeat the test.
Table 174: Expansion Interface 2-Way Transmission Test (#241) (continued)
Error
Code
Test
Result
Description / Recommendation
3 of 8