Communication Manager Maintenance-Object Repair Procedures
726 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1141 ABRT The PKT-CTRL is out-of-service.
1. Refer to PKT-CTRL (Packet Control Circuit Pack) Maintenance
documentation.
2. If step 1 does not resolve the problem, escalate to the next tier.
1187 ABRT The circuit pack, port or station may have been busied out by a technician.
1. Look in the Error Log for Error Type 18 (busied out) for BRI-BD,
BRI-PORT, or BRI-SET.
a. If this error type is present for BRI-SET only, use release
station to release the station.
b. If this error type is present for BRI-PORT and BRI-SET, use
release port location and run the test again.
c. If the error is present for BRI-BD, BRI-PORT, and BRI-SET, use
release port location to release the circuit pack, and run the
test again.
If the error is present for BRI-SET only, use release port
location to release the circuit pack, and run the test again.
If the error is present for both BRI-BD and BRI-PORT, use release
board location to release the circuit pack, and run the test
again.
Note:
Note: When you release the circuit pack, you release every port
associated with it. If ports still need to be busied out, use
busyout port location.
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
4. If the test continues to abort, escalate the problem.
2012 ABRT Internal system error.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
Table 245: Test #628 BRI XID (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 3