ATM-EI (Expansion Interface Circuit Pack)
Issue 1 June 2005 563
1407 ABRT This test cannot be run on an ATM-EI board that is on the active PNC
because it cannot be busied out. This error code indicates that PNC
duplication is enabled.
1. Attempt to perform a PNC interchange with the reset pnc
interchange command.
2. If the PNC interchange is successful, busyout the original
ATM-Expansion Interface circuit pack with the busyout board
location (address of the original ATM-EI board) command.
3. Retry the command.
2000 ABRT Response to the test was not received in the allowable time period.
1. Retry the command at 1-minute intervals up to 3 times.
2060 ABRT The link on the packet bus being used to perform the test has failed.
1. Retry the command at 1-minute intervals up to 3 times.
2. If the test continues to abort, resolve any PKT-INTF errors.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2500 ABRT Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
1 FAIL The test did not detect the test tone through the loop-around connection.
Note:
Note: The packet portion of this test was not run since the circuit
portion failed.
1. Test the active Tone-Clock (test tone-clock location) in the PN
that contains the defective ATM-EI circuit pack to verify that dial tone is
being supplied.
2. If the Tone-Clock is healthy, test the ATM-EI circuit pack (test board
location long).
3. If this test continues to fail, replace the ATM-EI circuit pack or
transceiver.
4. Test the new ATM-EI circuit pack (test board location long).
Table 181: ATM Board Framer Loop-Around Test (#1260) (continued)
Error
Code
Test
Result
Description / Recommendation
3 of 5