RANL-STA (Remote Analog Line (Station) Port)
Issue 1 June 2005 1921
1000 ABRT System resources required to run this test are not available. The port may
be busy with a valid call. This result is also reported for the system’s
Music-On-Hold port when it is off-hook, which it usually is.
1. Enter display port location to determine the station’s extension.
Enter status station extension to determine the service state of
the port. If the port is in use, wait until the port is idle.
2. Retry the command at 1-minute intervals up to 5 times.
1004 ABRT The port was seized by a valid call during the test. The test has been
aborted. Use display port location to determine the station
extension. Use status station to determine the service state of the
port. If the port is in use, wait until the port is idle.
1. Retry the command at 1-minute intervals up to 5 times.
1005 ABRT The test was aborted due to a configuration problem. This test may not be
applicable, or it may be disruptive to terminal equipment other than a voice
terminal (for example, the modem pool member or Music On Hold).
1018 ABRT The test has been disabled by administration. The default for the Test field
on the Station screen is y.
1. Determine why this field has been set to n on this station (this may be
due to the ringing application test 48, which can be customer or terminal
disturbing).
2. To enable the test for the particular analog station being tested, enter
change station extension and set the Test field to y.
1392 ABRT This port is currently a TTI port and the test will not execute on it.
1. Verify that the port is a TTI port using display port (the display
shows that the port is a TTI port) or list config (the display shows a
t for the port).
2. If the port is not a TTI port, escalate the problem. If both commands
indicate that the port is a TTI port, the abort is correct for the test, and
no action is necessary.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
Table 705: Test #35 Battery Feed Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 3