Communication Manager Maintenance-Object Repair Procedures
656 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
AUDIX-BD (AUDIX Circuit Pack)
S8700 | 8710 / S8500
The AUDIX-BD MO represents a TN566/TN2169 EMBEDDED AUDIX circuit pack combination.
For circuit-pack-level problems, see XXX-BD (Common Port Circuit Pack/Media Module)
on
page 2539.
EMBEDDED AUDIX consists of a combination of two circuit packs that occupy five slots on a
port carrier. The tests described in this manual apply only to switch-side maintenance that tests
a circuit pack’s components related to the TDM-bus interface. The AUDIX system has an
extensive maintenance strategy that is described in DEFINITY AUDIX System Release 3.2.4
Maintenance, 585-300-110
MO Name in Alarm Log Alarm
Level
Initial Command to Run Full Name of MO
AUDIX-BD MIN test board location sh AUDIX circuit pack
AUDIX-BD WRN test board location sh AUDIX circuit pack