Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
SNI-BD (SNI Circuit Pack)
Issue 1 June 2005 2087
120 FAIL The SNI circuit pack cannot communicate with the equipped SNI in slot
20.
1. Perform the Fiber link fault isolation
procedure in Maintenance
Procedures (03-300192). This will resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 3841, replace the
SNI being tested. Replacing an SNI may be service interrupting. See
SNI-BD (SNI Circuit Pack)
on page 2046 for the procedure for
replacing an SNI. To view SNI-PEER errors, use display errors
with category PNC-PEER. Retry the command.
3. If the SNI being tested has SNI-PEER Error Type 3841, replace the
SNI in slot 20. Replacing an SNI may be service interrupting. See
SNI-BD (SNI Circuit Pack)
on page 2046 for the procedure for
replacing an SNI. Retry the command.
133 FAIL No neighbor link is administered, but the SNI has an EI neighbor.
1. Administer the SNI on a fiber link to the EI neighbor it is connected to
using add fiber-link next. Or remove both fiber endpoints (i.e.,
this SNI and its EI neighbor) and remove the fiber endpoints from
circuit pack administration using change circuit-pack.
134 FAIL No neighbor link is administered, but the SNI has an SNI neighbor.
1. Administer the SNI on a fiber link to the SNI neighbor it is connected
to using add fiber-link next. Or remove both fiber endpoints
(i.e., this SNI and its SNI neighbor) and remove the fiber endpoints
from circuit pack administration using change circuit-pack.
135 FAIL The SNI circuit pack cannot communicate with its neighbor. The SNI has
an administered neighbor, but cannot communicate with its neighbor.
1. Check if the administered neighbor is inserted. If not, insert the
neighbor circuit pack.
2. Perform the Fiber link fault isolation procedure in Maintenance
Procedures (03-300192).
136 FAIL The SIN’s administered neighbor does not match the physical neighbor
connected. The type of neighbor administered is an SNI and the type of
neighbor physically connected is an EI.
1. Enter list fiber-link, and verify that the fiber-optic and metallic
cable connections are installed as administered.
Table 752: TEST #759 Configuration Audit (continued)
Error
Code
Test
Result
Description / Recommendation
11 of 13